This release news includes 2023.1.19 and 2024.10.1 and are available on My Symetri -> Applications
Fixes
- Audit Trail - issues by caused by multiple links in model has been solved.
- Audit Trail Accept Changes - issues by caused by multiple links in model has been solved.
- Audit Trail Reset - issues by caused by multiple links in model has been solved.
- Audit Trail Resolve - issues by caused by multiple links in model has been solved.
Bimfire Template Updates
Several improvements have been made to the Naviate Bimfire Templates.
Sweden
- Updated NV_ExternalFireSpreadWindow with two different width parameter for sides and top/Bottom
- Changed category for NV_Cutcube, NV_CutCubeL & NV_CutCylinder to Pier, and edited the family to enable being able to cut wall compartments again. Removed that piers are exported with IFC.
- Created an NV_Insatsplan symbol.
- Updated and fliped the EfterlysandeSkyltRullstol's diagonal.
- Updated thumbnail for undefined wall requirement.
- Updated Safe Refuge family, was bugs when changes sizes.
- Added new families from Informationsmodell för digitalt brandskydd.
- Renamed the diamond shaped Door/Window Requirements to old_Door/WindowRequirements, instead the new will only have text for doors and a text with border for windows - Still following SIS Bygghandlingar 10.11, and harmonising with other regions.
- Added families NV_Dörrstängare,NV_Plattformshiss, and added same parameters into the project and assigned to doors.
- Updated WallRequirement families, so NVWallWidth has been changed from a text parameter to a length parameter, now it's possible to add realistic thickness automatically from global, individually width instead of uniform. ATM doesn't work with adaptive, due to they don't have any thickness for curved walls. Works with the Soffit adaptive family. Control all via Global parameters.
- Removed Fire_EvacuationRouteDirection/AccessPointDirection,and added NV_Angreppsväg, NV_Utrymningsväg & NV_FrångängligUtrymningsväg.
- Changed WallRequirement control parameters from Shared to Family parameter, this removes the parameters from schedules and cleans up the model.
- Added a view filter on views for sheets to hide all section type who are not SectionsForSheets,, turned off Matchline by default.
- Added families for Insatsplaner, and created tags to be used for floor plans. There are now also View Types for Insatsplan which uses view filters to filter away all components who doesn't have a value on the parameter NVInsatsplan. Add a parameter on space for colouring the spaces, NVInsatsplanRumsfunktion
- Adding the parameter "Fire_FamilyTagMapping" as a family parameter instead of a project parameter, enabling the possibility to move the symbols to the custom templates without having to enter the values again. Same way the tags works. Removed the project parameter Fire_FamilyTagMapping.
- Added a new viewtype, "Coordination - By Linked Views", which by default only show wall compartmentation, which can be used by i.e. Architects when linking regulatory models and easily show minimum requirements in their views. See 00 ADMIN -> 03 BY LINKED VIEW in project browser.
- Updated ColumnRequirement family, control the size of the plan symbol with one parameter now instead of 1_S, 1_M & 1_L.
- Added more sizes for some tags such as NV_FireProtectionTag_FireReqFireRatingWall, enabling more flexibility in drawing design.
- Updated all Fire alarm devices with the prefix Fire_, added a parameter "NVVisibleOnEvacuationPlan" so the new Insatsplans symbols don't get tagged on evacuation plans. All values with not "Yes" will be hidden in the floor plan. So all Fire_ symbols has default value "No".
- Changed name on "Base Level" to "Default Level" after user feedback.
- Updated Evacuation plan landscape and portrait titleblocks, and added a default text that can be used for inspiration.
- Added a new Fire Protection tag for FireReq_FireRatingWindows, this can be used in elevactions / section to show the rating of a certain window. Due to Annotation Categories can't be placed in elevation views, so a manual addition is needed.
Norway
- Changed category for NV_Cutcube, NV_CutCubeL & NV_CutCylinder to Pier, and edited the family to enable being able to cut wall compartments again. Removed that piers are exported with IFC.
- Updated Safe Refuge family, was bugs when changes sizes.
- Linked new 3924:2024 families to ISO 7010:2020 tags for evacuation plans.
- Updated WallRequirement families, so NVWallWidth has been changed from a text parameter to a length parameter, now it's possible to add realistic thickness automatically from global, individually width instead of uniform. ATM doesn't work with adaptive, due to they don't have any thickness for curved walls. Works with the Soffit adaptive family. Control all via Global parameters.
- Changed 1_S / 1_M / 1_L on the new 3924:2024 symbols to the correct size, so they are called something like 500x500, 750x750, 1.5mm etc..
- Updated Fluktveier, Angreppsvei and Huvedangrepsvei arrow design.
- Added a view filter on views for sheets to hide all section type who are not SectionsForSheets,, turned off Matchline by default.
- Adding the parameter "Fire_FamilyTagMapping" as a family parameter instead of a project parameter, enabling the possibility to move the symbols to the custom templates without having to enter the values again. Same way the tags works. Removed the project parameter Fire_FamilyTagMapping.
- Added a new viewtype, "Coordination - By Linked Views", which by default only show wall compartmentation, which can be used by i.e. Architects when linking regulatory models and easily show minimum requirements in their views.
- Changed name on "Base Level" to "Default Level" after user feedback.
- Updated Evacuation plan landscape and portrait titleblocks, and added a default text that can be used for inspiration.
- Added a new Fire Protection tag for FireReq_FireRatingWindows, this can be used in elevactions / section to show the rating of a certain window. Due to Annotation Categories can't be placed in elevation views, so a manual addition is needed.
UAE
- Changed category for NV_Cutcube, NV_CutCubeL & NV_CutCylinder to Pier, and edited the family to enable being able to cut wall compartments again. Removed that piers are exported with IFC.
- Updated Safe Refuge family, was bugs when changes sizes.
- Updated WallRequirement families, so NVWallWidth has been changed from a text parameter to a length parameter, now it's possible to add realistic thickness automatically from global, individually width instead of uniform. ATM doesn't work with adaptive, due to they don't have any thickness for curved walls. Works with the Soffit adaptive family. Control all via Global parameters.
- Updated the size parameters and changed renamed from 1_S,1_M & 1_L to the real sizes i.e. 500x500, 750x750 etc.
- Added a view filter on views for sheets to hide all section type who are not SectionsForSheets,, turned off Matchline by default.
- Adding the parameter "Fire_FamilyTagMapping" as a family parameter instead of a project parameter, enabling the possibility to move the symbols to the custom templates without having to enter the values again. Same way the tags works. Removed the project parameter Fire_FamilyTagMapping.
- Added a new viewtype, "Coordination - By Linked Views", which by default only show wall compartmentation, which can be used by i.e. Architects when linking regulatory models and easily show minimum requirements in their views.
- Changed name on "Base Level" to "Default Level" after user feedback.
- Updated Evacuation plan landscape and portrait titleblocks, and added a default text that can be used for inspiration.
- Added a new Fire Protection tag for FireReq_FireRatingWindows, this can be used in elevactions / section to show the rating of a certain window. Due to Annotation Categories can't be placed in elevation views, so a manual addition is needed.
Hungary
- 1. Updated NV_ExternalFireSpreadWindow with two different width parameter for sides and top/Bottom.
- Changed category for NV_Cutcube, NV_CutCubeL & NV_CutCylinder to Pier, and edited the family to enable being able to cut wall compartments again. Removed that piers are exported with IFC.
- Updated Safe Refuge family, was bugs when changes sizes.
- Updated WallRequirement families, so NVWallWidth has been changed from a text parameter to a length parameter, now it's possible to add realistic thickness automatically from global, individually width instead of uniform. ATM doesn't work with adaptive, due to they don't have any thickness for curved walls. Works with the Soffit adaptive family. Control all via Global parameters.
- Changed naming of the sizes for the regional content from 1_S, 1_M & 1_L to real size, such as 500x500, 750x750 etc.
- Added a view filter on views for sheets to hide all section type who are not SectionsForSheets,, turned off Matchline by default.
- Adding the parameter "Fire_FamilyTagMapping" as a family parameter instead of a project parameter, enabling the possibility to move the symbols to the custom templates without having to enter the values again. Same way the tags works. Removed the project parameter Fire_FamilyTagMapping.
- Added a new view type, "Coordination - By Linked Views", which by default only show wall compartmentation, which can be used by i.e. Architects when linking regulatory models and easily show minimum requirements in their views.
- Changed name on "Base Level" to "Default Level" after user feedback.
- Updated Evacuation plan landscape and portrait titleblocks, and added a default text that can be used for inspiration.
- Added a new Fire Protection tag for FireReq_FireRatingWindows, this can be used in elevactions / section to show the rating of a certain window. Due to Annotation Categories can't be placed in elevation views, so a manual addition is needed.
UK
- 1. Changed category for NV_Cutcube, NV_CutCubeL & NV_CutCylinder to Pier, and edited the family to enable being able to cut wall compartments again. Removed that piers are exported with IFC.
- Updated Safe Refuge family, was bugs when changes sizes.
- Edited the wall compartmentation to enable more flexibility for the end user, removing formulas withing the family. Remember, if changing material / colours it's necessary to update the thumbnails (type image).
- Updated WallRequirement families, so NVWallWidth has been changed from a text parameter to a length parameter, now it's possible to add realistic thickness automatically from global, individually width instead of uniform. ATM doesn't work with adaptive, due to they don't have any thickness for curved walls. Works with the Soffit adaptive family. Control all via Global parameters.
- Added a view filter on views for sheets to hide all section type who are not SectionsForSheets,, turned off Matchline by default.
- Adding the parameter "Fire_FamilyTagMapping" as a family parameter instead of a project parameter, enabling the possibility to move the symbols to the custom templates without having to enter the values again. Same way the tags works. Removed the project parameter Fire_FamilyTagMapping.
- Added a new viewtype, "Coordination - By Linked Views", which by default only show wall compartmentation, which can be used by i.e. Architects when linking regulatory models and easily show minimum requirements in their views.
- Changed name on "Base Level" to "Default Level" after user feedback.
- Updated Evacuation plan landscape and portrait titleblocks, and added a default text that can be used for inspiration.
- Added a new Fire Protection tag for FireReq_FireRatingWindows, this can be used in elevactions / section to show the rating of a certain window. Due to Annotation Categories can't be placed in elevation views, so a manual addition is needed.
Denmark
- Changed category for NV_Cutcube, NV_CutCubeL & NV_CutCylinder to Pier, and edited the family to enable being able to cut wall compartments again. Removed that piers are exported with IFC.
- Updated Safe Refuge family, was bugs when changes sizes.
- Updated WallRequirement families, so NVWallWidth has been changed from a text parameter to a length parameter, now it's possible to add realistic thickness automatically from global, individually width instead of uniform. ATM doesn't work with adaptive, due to they don't have any thickness for curved walls. Works with the Soffit adaptive family. Control all via Global parameters.
- Added a view filter on views for sheets to hide all section type who are not SectionsForSheets,, turned off Matchline by default.
- Adding the parameter "Fire_FamilyTagMapping" as a family parameter instead of a project parameter, enabling the possibility to move the symbols to the custom templates without having to enter the values again. Same way the tags works. Removed the project parameter Fire_FamilyTagMapping.
- Added a new view type, "Coordination - By Linked Views", which by default only show wall compartmentation, which can be used by i.e. Architects when linking regulatory models and easily show minimum requirements in their views.
- Changed name on "Base Level" to "Default Level" after user feedback.
- Updated Evacuation plan landscape and portrait titleblocks, and added a default text that can be used for inspiration.
- Added a new Fire Protection tag for FireReq_FireRatingWindows, this can be used in elevactions / section to show the rating of a certain window. Due to Annotation Categories can't be placed in elevation views, so a manual addition is needed.
The Netherlands
- Changed category for NV_Cutcube, NV_CutCubeL & NV_CutCylinder to Pier, and edited the family to enable being able to cut wall compartments again. Removed that piers are exported with IFC.
- Updated Safe Refuge family, was bugs when changes sizes.
- Updated WallRequirement families, so NVWallWidth has been changed from a text parameter to a length parameter, now it's possible to add realistic thickness automatically from global, individually width instead of uniform. ATM doesn't work with adaptive, due to they don't have any thickness for curved walls. Works with the Soffit adaptive family. Control all via Global parameters.
- Changed parameters from 1_S/1_M/1_L to the real sizes of the local symbols. So now they are 500x500, 1000x1000x, 1000x500, 2.0mm etc.
- Added a view filter on views for sheets to hide all section type who are not SectionsForSheets,, turned off Matchline by default.
- Adding the parameter "Fire_FamilyTagMapping" as a family parameter instead of a project parameter, enabling the possibility to move the symbols to the custom templates without having to enter the values again. Same way the tags works. Removed the project parameter Fire_FamilyTagMapping.
- Added a new view type, "Coordination - By Linked Views", which by default only show wall compartmentation, which can be used by i.e. Architects when linking regulatory models and easily show minimum requirements in their views.
- Changed name on "Base Level" to "Default Level" after user feedback.
- Updated Evacuation plan landscape and portrait titleblocks, and added a default text that can be used for inspiration.
- Added a new Fire Protection tag for FireReq_FireRatingWindows, this can be used in elevactions / section to show the rating of a certain window. Due to Annotation Categories can't be placed in elevation views, so a manual addition is needed.
Finland
- Changed category for NV_Cutcube, NV_CutCubeL & NV_CutCylinder to Pier, and edited the family to enable being able to cut wall compartments again. Removed that piers are exported with IFC.
- Updated Safe Refuge family, was bugs when changes sizes
- Updated WallRequirement families, so NVWallWidth has been changed from a text parameter to a length parameter, now it's possible to add realistic thickness automatically from global, individually width instead of uniform. ATM doesn't work with adaptive, due to they don't have any thickness for curved walls. Works with the Soffit adaptive family. Control all via Global parameters.
- Added a view filter on views for sheets to hide all section type who are not SectionsForSheets,, turned off Matchline by default.
- Adding the parameter "Fire_FamilyTagMapping" as a family parameter instead of a project parameter, enabling the possibility to move the symbols to the custom templates without having to enter the values again. Same way the tags works. Removed the project parameter Fire_FamilyTagMapping.
- Added a new view type, "Coordination - By Linked Views", which by default only show wall compartmentation, which can be used by i.e. Architects when linking regulatory models and easily show minimum requirements in their views.
- Changed name on "Base Level" to "Default Level" after user feedback.
- Updated Evacuation plan landscape and portrait titleblocks, and added a default text that can be used for inspiration.
- Added a new Fire Protection tag for FireReq_FireRatingWindows, this can be used in elevactions / section to show the rating of a certain window. Due to Annotation Categories can't be placed in elevation views, so a manual addition is needed.
Improved compatibility with other Revit add-ins
We have made background changes to reduce the risk of conflicts when running Naviate applications alongside other Revit plugins.
Previously, a shared software component (System.Text.Json) could clash with the same component used by other add-ins, in some cases causing Naviate products or other plugins to stop working. We have removed this dependency to lower the risk of such conflicts occurring.
Please note: While this update significantly reduces the likelihood of compatibility issues, it does not eliminate all possible conflicts with third-party plugins. If you experience any issues, please contact our support team.
Help Center